Optoma WU334 projector lamp
The Optoma WU334 takes lamp BL-FP240G rated for 3,500 hours (15,000 hours in eco mode) . It comes as a complete module, with the bulb already fitted in its housing. The same lamp is also sold under 1 other part number, all listed below. It fits 25 Optoma models in total.
Replacing the Optoma WU334 lamp.
The Optoma WU334 uses the BL-FP240G lamp, also sold as SP.7AZ01GC01. It is a 240W P-VIP bulb rated for 3,500 hours in normal mode and 15,000 hours in eco mode. BL-FP240G is the complete module, with the bulb already fitted.
The Optoma WU334 is a WUXGA DLP projector with a 0.48-inch display, 1920x1200 resolution and 3,600 ANSI lumens. It was released in December 2017 and discontinued in March 2021. Twenty-four other Optoma models share this lamp, including the DH350, EH334 and HD143X.
Before you order, check the code printed on your old lamp or the model label. Choose the module for the quicker swap. Every lamp we sell carries a genuine OEM burner. Each one has a 180-day guarantee from the day it arrives, with a replacement or refund. After fitting, reset the lamp-hour counter from the projector's menu, and follow the user manual.
Checked against our catalogue and the projector's published specifications, October 2026.Every code this lamp is sold under.
The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the Optoma WU334.
Check the code before you order
The code on your old lamp or its housing should match one of the codes listed. Optoma and third-party suppliers sell the same lamp under several numbers.
Not sure it's your model?
The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.
Optoma WU334 specifications.
The figures that matter when you replace the lamp, plus the projector's key specs.
This lamp also fits 24 other Optoma models.
If your projector is one of these rather than the WU334, the same lamp is the correct part.
Common questions.
Which lamp does the Optoma WU334 use?
The Optoma WU334 uses the BL-FP240G lamp, a 240W P-VIP bulb. BL-FP240G is the complete module, with the bulb already fitted in its housing. The lamp is also sold as SP.7AZ01GC01. It is rated for 3,500 hours in normal mode and 15,000 hours in eco mode.
What other part numbers fit the Optoma WU334?
The Optoma WU334 lamp is also sold as SP.7AZ01GC01, so that is the other part number listed for this projector. SP.7AZ01GC01 is the complete module, with the bulb already fitted in its housing. BL-FP240G is the primary part number for this 240W P-VIP bulb.
How long does the Optoma WU334 lamp last?
The Optoma WU334 lamp has a rated life of 3,500 hours in normal mode and 15,000 hours in eco mode. You can check the lamp-hour reading in the projector's menu to see how much of that life has been used. Once the reading approaches the rated life for your mode, plan a replacement.
Should I buy the module or the bare bulb for the Optoma WU334?
For the Optoma WU334, buy the module (BL-FP240G) for the quicker swap. The module comes with the bulb already fitted in its housing. We do not sell a bare bulb option for this projector, so the complete module is the only way to replace the lamp.
Which other Optoma projectors use the same lamp?
The Optoma DH350, EH334 and HD143X use the same lamp as the WU334, the 240W P-VIP bulb listed as BL-FP240G. Twenty-four other Optoma projectors share this lamp, so owners of those models can order the BL-FP240G module.
The Optoma WU334 lamp at a glance.
Replacing the lamp in the Optoma WU334.
- Switch the projector off and let it cool for at least 30 minutes, then disconnect the power cord.
- Loosen the screw on the lamp cover and take the cover off (the screw stays captive in the cover).
- Loosen the screw holding the lamp module, lift the lamp handle and unplug the lamp cord.
- Lift the lamp module out carefully; do not touch the lamp glass, as hand oil can make it shatter (wipe with a dry cloth if touched).
- Fit the new module by reversing these steps; the projector will not power on unless the lamp cover is refitted.
- Turn the projector on and reset the lamp timer.
Then reset the lamp timer.
Until you reset it, the WU334 keeps counting from the old lamp's hours and will warn that the new lamp is expiring.