Optoma EH334 projector lamp
The Optoma EH334 takes lamp BL-FP240G rated for 3,500 hours (15,000 hours in eco mode) . It comes as a complete module, with the bulb already fitted in its housing. The same lamp is also sold under 1 other part number, all listed below. It fits 25 Optoma models in total.
Replacing the Optoma EH334 lamp.
The Optoma EH334 uses the BL-FP240G lamp, also sold as SP.7AZ01GC01. The lamp is a 240W P-VIP bulb rated for 3,500 hours in normal mode and 15,000 hours in eco mode. We sell it as a complete module, with the bulb already fitted in its housing, which makes the swap quicker.
The EH334 is a DLP projector with a 0.48-inch display, 1920x1080 (HD) resolution and 3,600 ANSI lumens. It was released in February 2018 and discontinued in February 2020. Its lamp is also used by 24 other models, including the DH350, EH335, EH336 and EH337. Owners of those models need the same lamp.
Check the code printed on the old lamp or the projector's model label before ordering, since BL-FP240G and SP.7AZ01GC01 both refer to this module. After fitting, reset the lamp-hour counter from the projector's menu. Every lamp we sell carries a genuine OEM burner, and comes with a 180-day guarantee from the day it arrives, with replacement or refund. If we get the fitment wrong, the return costs you nothing.
Checked against our catalogue and the projector's published specifications, October 2026.Every code this lamp is sold under.
The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the Optoma EH334.
Check the code before you order
The code on your old lamp or its housing should match one of the codes listed. Optoma and third-party suppliers sell the same lamp under several numbers.
Not sure it's your model?
The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.
Optoma EH334 specifications.
The figures that matter when you replace the lamp, plus the projector's key specs.
This lamp also fits 24 other Optoma models.
If your projector is one of these rather than the EH334, the same lamp is the correct part.
Common questions.
Which lamp does the Optoma EH334 use?
The Optoma EH334 uses the BL-FP240G lamp, also sold as SP.7AZ01GC01. It is a 240W P-VIP bulb supplied as a complete module, already fitted in its housing. Its rated life is 3,500 hours in normal mode and 15,000 hours in eco mode.
Is SP.7AZ01GC01 the same as BL-FP240G for the Optoma EH334?
Yes, SP.7AZ01GC01 is an equivalent code for the BL-FP240G lamp used in the Optoma EH334. Both codes refer to the same complete module, with the bulb already fitted in its housing, so either part number fits this projector. If your old lamp shows either code, this is the replacement you need.
How long does the Optoma EH334 lamp last?
The Optoma EH334 lamp, the BL-FP240G module, is rated for 3,500 hours in normal mode and 15,000 hours in eco mode. The eco rating is the longer of the two, so running the projector in eco mode gives the longest rated life.
Which other Optoma projectors use the same lamp as the EH334?
24 other Optoma projectors use the same BL-FP240G lamp as the EH334, including the DH350, EH335, EH336 and EH337. Owners of those models need the same BL-FP240G lamp, which is also sold as SP.7AZ01GC01 and comes as a complete module.
How fast is delivery for the Optoma EH334 lamp?
Delivery for the Optoma EH334 lamp takes 3 to 7 working days to the Middle East and Africa, and around 5 to 9 working days to the rest of the world. Shipping is included in the price shown online, so there is no extra delivery charge.
The Optoma EH334 lamp at a glance.
Replacing the lamp in the Optoma EH334.
- Switch the projector off and let it cool for at least 30 minutes, then disconnect the power cord.
- Loosen the screw on the lamp cover and take the cover off (the screw stays captive in the cover).
- Loosen the screw holding the lamp module, lift the lamp handle and unplug the lamp cord.
- Lift the lamp module out carefully; do not touch the lamp glass, as hand oil can make it shatter (wipe with a dry cloth if touched).
- Fit the new module by reversing these steps; the projector will not power on unless the lamp cover is refitted.
- Turn the projector on and reset the lamp timer.
Then reset the lamp timer.
Until you reset it, the EH334 keeps counting from the old lamp's hours and will warn that the new lamp is expiring.