Sony VPL-VW50 projector lamp
The Sony VPL-VW50 takes lamp LMP-H200, a 200 W lamp . It is available both as a complete module (bulb fitted in its housing) and as a bare bulb for re-using your existing housing. The same lamp is also sold under 1 other part number, all listed below. It fits 12 Sony models in total.
Replacing the Sony VPL-VW50 lamp.
The Sony VPL-VW50 uses the LMP-H200 lamp, also sold as 994802350. It is a 200W UHP bulb. It comes as a complete module or as a bare bulb for your existing housing.
The VPL-VW50 is a three-panel SXRD projector, with 0.61-inch panels at 1920x1080 resolution in 16:9 format. It gives 900 lumens (ANSI) brightness with 15,000:1 contrast. It was released in October 2006 and discontinued in January 2008. 11 other models use this lamp too, including the BRAVIA VPL-VW40, BRAVIA VPL-VW50 1080p and BRAVIA VPL-VW60.
Before ordering, check the code on your old lamp or the projector's model label. Both LMP-H200 and 994802350 identify the same lamp. A module saves time, since the bulb is already fitted in its housing. The bare bulb re-uses your existing housing and costs less, but you move it across by hand. After fitting, reset the lamp-hour counter from the projector's menu and follow the user manual. Our 180-day guarantee runs from the day the lamp arrives, with a replacement or refund.
Checked against our catalogue and the projector's published specifications, October 2026.Every code this lamp is sold under.
The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the Sony VPL-VW50.
Check the code before you order
The code on your old lamp or its housing should match one of the codes listed. Sony and third-party suppliers sell the same lamp under several numbers.
Not sure it's your model?
The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.
Sony VPL-VW50 specifications.
The figures that matter when you replace the lamp, plus the projector's key specs.
This lamp also fits 11 other Sony models.
If your projector is one of these rather than the VPL-VW50, the same lamp is the correct part.
Common questions.
Which lamp does the Sony VPL-VW50 use?
The Sony VPL-VW50 uses the LMP-H200 lamp, a 200W UHP bulb. It is also sold as 994802350. It is available as a complete module with the bulb fitted in its housing, or as a bare bulb for your existing housing.
Is 994802350 the same as LMP-H200 for the Sony VPL-VW50?
Yes, 994802350 is another code for the LMP-H200 lamp, so it fits the Sony VPL-VW50. It is listed for both the complete module and the bare bulb. Both codes point to one lamp for this projector.
Should I buy the module or the bare bulb for the Sony VPL-VW50?
For the Sony VPL-VW50, the module is the easier choice, since its LMP-H200 bulb is already fitted in its housing. A bare bulb costs less if you keep your existing housing, but you move the bulb across by hand. Both use a 200W UHP bulb.
Which other Sony projectors use the same lamp as the VPL-VW50?
11 other models use the LMP-H200 lamp alongside the Sony VPL-VW50, including the BRAVIA VPL-VW40, BRAVIA VPL-VW50 1080p and BRAVIA VPL-VW60. Owners of those models can order the same module or bare bulb listed on this page. The lamp is a 200W UHP bulb.
How fast is delivery for the Sony VPL-VW50 lamp?
The Sony VPL-VW50 lamp, LMP-H200, is delivered in 3–7 working days to the Middle East and Africa. The rest of the world takes around 5–9 working days. Prices shown online are delivered prices, with shipping included.
The Sony VPL-VW50 lamp at a glance.
Replacing the lamp in the Sony VPL-VW50.
- Turn the projector off and unplug the AC power cord; the lamp stays hot, so wait at least an hour (take extra care if ceiling-mounted).
- Lay a cloth down and turn the projector upside down onto it, so pieces of a damaged lamp cannot scatter.
- Loosen the lamp cover screw with a Phillips screwdriver and open the cover.
- Loosen the three screws on the lamp, raise the cover release lever and pull the lamp straight out, keeping it level.
- Push the new lamp all the way in, tighten its three screws and put the release lever back, without touching the optical block inside.
- Close the lamp cover and tighten the screw.
- Fit a new air filter every time the lamp is replaced.
Then reset the lamp timer.
Until you reset it, the VPL-VW50 keeps counting from the old lamp's hours and will warn that the new lamp is expiring.