Optoma TX800 projector – image: Optoma

Optoma TX800 projector lamp

The Optoma TX800 takes lamp SP.85R01G.C01 rated for 2,000 hours (3,000 hours in eco mode) . It comes as a complete module, with the bulb already fitted in its housing. The same lamp is also sold under 6 other part numbers, all listed below. It fits 12 Optoma models in total.

Display Type0.55" DLP x 1
Resolution1024x768
Brightness2,500 Lumens
Light Source230W SHP bulb
SP.85R01G.C01 lamp with housing for the Optoma TX800
✓The lamp that fits SP.85R01G.C01 projector lamp with module Primary code SP.85R01G.C01
Lamp with housingFits 14 models
Price on request Delivered price confirmed within one business hour. Full lamp details

Replacing the Optoma TX800 lamp.

The Optoma TX800 uses the SP.85R01GC01 lamp, which we sell as part number SP.85R01G.C01. It is also sold as BL-FP230C, 60-201608, BL-FP230B and SP.85R01G.001. The projector's light source is a 230 W SHP bulb, rated at 2,000 hours in normal mode and 3,000 hours in eco mode. We sell it as a complete module, with the bulb already fitted in its housing.

The TX800 is a 1024x768 XGA DLP projector with a single 0.55-inch chip, rated at 2,500 lumens (ANSI) with a 2,200:1 contrast ratio. It was released in October 2006 and discontinued in September 2008. The lamp is shared with 11 other models, including the DX625, DX733, EP749 and EzPro 749.

Confirm the code on the old lamp or the projector label, since the model has several equivalent codes. Either SP.85R01GC01 or BL-FP230C identifies this module, so match whichever is printed on your lamp. Once fitted, reset the lamp-hour counter from the projector's menu, and follow the user manual.

Checked against our catalogue and the projector's published specifications, October 2026.

Every code this lamp is sold under.

The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the Optoma TX800.

CodeUsed by
SP.85R01G.C01Optoma original part number
60 201608Equivalent code
60-201608Equivalent code
BL-FP230CEquivalent code
SP.85R01GC01Equivalent code
BL-FP230BEquivalent code
SP.85R01G.001Equivalent code

Check the code before you order

The code on your old lamp or its housing should match one of the codes listed. Optoma and third-party suppliers sell the same lamp under several numbers.

Not sure it's your model?

The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.

Optoma TX800 specifications.

The figures that matter when you replace the lamp, plus the projector's key specs.

StatusDiscontinued Sep 2008
ReleasedOctober 2006
Display Type0.55" DLP x 1
Resolution1024x768
Aspect Ratio4:3 (XGA)
Brightness2,500 Lumens (ANSI)
Contrast2,200:1 (full on/off)
Light Source230W SHP bulb
Light Source Life2,000 hours / 3,000 hours (Eco)
Throw Ratio1.94:1 - 2.13:1
Throw Distance3.9' - 39.4'
Image Size27.70" - 304.90"
Lens ShiftNo
Digital KeystoneVertical only
Projector Size3.80" x 9.30" x 8.20" (HxWxD)
Weight4.4 lbs
Power290 Watts 100V - 240V
Internal Speakers2.0 Watts Mono
Connection PanelRS232: DB-9pin
Warranty3 Years
Replacement lampSP.85R01GC01
Specifications: ProjectorCentral

This lamp also fits 11 other Optoma models.

If your projector is one of these rather than the TX800, the same lamp is the correct part.

Common questions.

Which lamp does the Optoma TX800 use?

The Optoma TX800 uses the SP.85R01GC01 lamp, which we sell as part number SP.85R01G.C01. It is a 230 W SHP lamp sold as a complete module. Its rated life is 2,000 hours in normal mode and 3,000 hours in eco mode.

Is BL-FP230C the same as SP.85R01GC01 for the Optoma TX800?

Yes, BL-FP230C is one of the alternative codes for the SP.85R01GC01 lamp in the Optoma TX800. The lamp is also sold as 60-201608, BL-FP230B and SP.85R01G.001, all of which identify the same complete module. We sell it as part number SP.85R01G.C01.

How long does the Optoma TX800 lamp last?

The Optoma TX800 lamp is rated for 2,000 hours in normal mode, and 3,000 hours in eco mode. Running the projector in eco mode gives the longer rated life. Read the projector's lamp-hour counter to see how close the lamp is to these figures.

Which other Optoma projectors use the same lamp as the TX800?

The Optoma TX800 shares its SP.85R01GC01 lamp with 11 other models. These include the DX205, DX670, EP719H and OP722. Owners of those projectors can check the code on their old lamp against the part number SP.85R01G.C01 before ordering.

What are the signs the Optoma TX800 lamp needs replacing?

The Optoma TX800 lamp is due for replacement when its lamp-hour reading approaches the rated life, or when the projector shows a lamp warning. Dimming or a color shift in the picture are other common signs.

All Optoma projector lamps → All Optoma projector models A–Z →

The Optoma TX800 lamp at a glance.

LampSP.85R01G.C01

Replacing the lamp in the Optoma TX800.

  1. Turn the projector off with the Power/Standby button.
  2. Let it cool for at least 30 minutes; the lamp compartment is hot.
  3. Disconnect the power cord.
  4. Undo the screw on the lamp cover with a screwdriver, then lift the cover up and off.
  5. Take out the two screws holding the lamp module and slide the module out.
  6. To avoid injury, do not drop the module or touch the bulb.
  7. Fit the new lamp module by reversing these steps.
Steps summarised from Optoma's manual for the TX800: source.

Then reset the lamp timer.

Until you reset it, the TX800 keeps counting from the old lamp's hours and will warn that the new lamp is expiring.

Menu → Lamp Setting → Reset Lamp Hours
Menu path from Optoma's manual: source.