Optoma PRO360W projector lamp
The Optoma PRO360W takes lamp SP.8LE01GC01 / BL-FP200H, a 200 W lamp rated for 3,000 hours. It is available both as a complete module (bulb fitted in its housing) and as a bare bulb for re-using your existing housing. The same lamp is also sold under 3 other part numbers, all listed below. It fits 22 Optoma models in total.
Replacing the Optoma PRO360W lamp.
The Optoma PRO360W uses the SP.8LE01GC01 lamp, also sold as BL-FP200H and SP.8FE01GC01. The lamp is a 200W P-VIP bulb with a rated life of 3,000 hours in normal mode and 6,000 hours in Eco mode. You can buy it as a complete module or as a bare bulb to fit your existing housing.
The Optoma PRO360W is a DLP projector with 1280x800 WXGA resolution and 3,000 lumens brightness. Optoma released the model in April 2011 and discontinued it in September 2013. Other Optoma models that share this lamp include the DP334, DP3505, DW312 and ES539. In total, 21 other models use this lamp.
Before you order, check the code printed on the old lamp or the model label on the projector, and match it to SP.8LE01GC01 or BL-FP200H. After fitting the new lamp, reset the lamp-hour counter from the projector's menu, and follow the user manual for the exact steps.
Checked against our catalogue and the projector's published specifications, October 2026.Every code this lamp is sold under.
The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the Optoma PRO360W.
Check the code before you order
The code on your old lamp or its housing should match one of the codes listed. Optoma and third-party suppliers sell the same lamp under several numbers.
Not sure it's your model?
The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.
Optoma PRO360W specifications.
The figures that matter when you replace the lamp, plus the projector's key specs.
This lamp also fits 21 other Optoma models.
If your projector is one of these rather than the PRO360W, the same lamp is the correct part.
Common questions.
Which lamp does the Optoma PRO360W use?
The Optoma PRO360W uses the SP.8LE01GC01 lamp, also sold as BL-FP200H. It is a 200W P-VIP bulb with a rated life of 3,000 hours in normal mode and 6,000 hours in Eco mode. You can buy it as a complete module or as a bare bulb to fit your existing housing.
Is BL-FP200H the same as SP.8LE01GC01 for the Optoma PRO360W?
Yes, BL-FP200H is an alternate code for the SP.8LE01GC01 lamp used in the Optoma PRO360W. Both codes refer to the same 200W P-VIP bulb. Either part number describes the lamp this projector takes. The SP.8LE01GC01 code is the main part number on this page.
How long does the Optoma PRO360W lamp last?
The Optoma PRO360W lamp, SP.8LE01GC01, is rated for 3,000 hours in normal mode and 6,000 hours in Eco mode. Eco mode gives the longer rated life. Those figures come from the projector's specification for its 200W P-VIP bulb.
Should I buy the module or the bare bulb for the Optoma PRO360W?
The Optoma PRO360W lamp is available as a complete module or a bare bulb. The complete module has the bulb fitted in its housing for a quicker swap. The bare bulb fits your existing housing and is cheaper. Both options have a 200W P-VIP bulb rated for 3,000 hours.
Which other Optoma projectors use the same lamp as the Optoma PRO360W?
21 other Optoma models use the same SP.8LE01GC01 lamp as the Optoma PRO360W. Examples include the DP334, DP3505, DW312 and ES539. Owners of those models can match their own lamp code against SP.8LE01GC01 or BL-FP200H.
The Optoma PRO360W lamp at a glance.
At four hours a day, that is roughly 2.1 years in normal mode or 4.1 years in eco mode before the PRO360W asks for a new lamp. Running it in eco mode is the single easiest way to stretch the lamp — at the cost of some brightness.
Replacing the lamp in the Optoma PRO360W.
- Turn the projector off with the power button.
- Let it cool for at least 30 minutes.
- Unplug the power cord.
- Loosen the two captive screws on the lamp cover and lift the cover off.
- Loosen the two captive screws on the lamp module, raise its handle and ease the module out slowly.
- Do not touch the lamp glass (hand oil can make it shatter); wipe it with a dry cloth if touched.
- The projector will not power on unless the lamp cover is back in place.
- After fitting the new lamp, switch on and run Lamp Reset.
Then reset the lamp timer.
Until you reset it, the PRO360W keeps counting from the old lamp's hours and will warn that the new lamp is expiring.