NEC GT5000 projector lamp
The NEC GT5000 takes lamp 001-715, a 275 W lamp rated for 1,500 hours. It is available both as a complete module (bulb fitted in its housing) and as a bare bulb for re-using your existing housing. The same lamp is also sold under 3 other part numbers, all listed below. It fits 6 NEC models in total.
Replacing the NEC GT5000 lamp.
The NEC GT5000 uses the 001-715 lamp, also sold as 456-9060. This 275W NSH bulb is rated for 1,500 hours in normal mode and 2,000 hours in eco mode. We sell it as a complete module with the bulb fitted in its housing, or as a bare bulb to fit your existing housing.
The GT5000 is a dual-lamp 3LCD projector with a 1.40-inch display, 1024x768 (XGA) resolution and 6,000 ANSI lumens. It was released in April 2003 and discontinued in October 2006. Its lamp is also used by 5 other models, including the GT5000+, GT6000 and GT6000+. Owners of those models need the same lamp.
Check the code printed on the old lamp or the projector's model label before ordering. After fitting, reset the lamp-hour counter from the projector's menu. Every lamp we sell carries a genuine OEM burner, and comes with a 180-day guarantee from the day it arrives, with replacement or refund. If we get the fitment wrong, the return costs you nothing.
Checked against our catalogue and the projector's published specifications, October 2026.Every code this lamp is sold under.
The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the NEC GT5000.
Check the code before you order
The code on your old lamp or its housing should match one of the codes listed. NEC and third-party suppliers sell the same lamp under several numbers.
Not sure it's your model?
The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.
NEC GT5000 specifications.
The figures that matter when you replace the lamp, plus the projector's key specs.
This lamp also fits 5 other NEC models.
If your projector is one of these rather than the GT5000, the same lamp is the correct part.
Common questions.
Which lamp does the NEC GT5000 use?
The NEC GT5000 uses the 001-715 lamp, also sold as 456-9060. It is a 275W NSH bulb rated for 1,500 hours in normal mode and 2,000 hours in eco mode. We supply it as a complete module or a bare bulb to fit your existing housing.
Is 456-9060 the same as 001-715 for the NEC GT5000?
Yes, 456-9060 is an equivalent code for the 001-715 lamp used in the NEC GT5000. Both codes refer to the same 275W NSH bulb, so either part number fits this projector. If your old lamp shows either code, this is the replacement you need.
How long does the NEC GT5000 lamp last?
The NEC GT5000 lamp, the 001-715 module or bare bulb, is rated for 1,500 hours in normal mode and 2,000 hours in eco mode. The eco rating is the longer of the two, so running the projector in eco mode gives the longest rated life.
Which other NEC projectors use the same lamp as the GT5000?
5 other NEC projectors use the same 001-715 lamp as the GT5000, including the GT5000+, GT6000 and GT6000+. Owners of those models need the same 001-715 lamp, which is also sold as 456-9060 and comes as a complete module or bare bulb.
How fast is delivery for the NEC GT5000 lamp?
Delivery for the NEC GT5000 lamp takes 3 to 7 working days to the Middle East and Africa, and around 5 to 9 working days to the rest of the world. Shipping is included in the price shown online, so there is no extra delivery charge.
The NEC GT5000 lamp at a glance.
At four hours a day, that is roughly 1.4 years in normal mode or 2.1 years in eco mode before the GT5000 asks for a new lamp. Running it in eco mode is the single easiest way to stretch the lamp — at the cost of some brightness.
Replacing the lamp in the NEC GT5000.
- Turn the projector off, let the cooling cycle finish, switch off the main power and unplug it; give the lamp at least an hour to cool before handling.
- Loosen the captive lamp-cover screw until it turns freely and remove the lamp cover.
- Loosen the two captive lamp-frame screws and pull the frame out by its handle; do not try to defeat the housing interlock.
- Push the new NEC lamp frame (GT60LP, or long-life GT60LPS) in until it seats in its connector, then tighten both screws firmly.
- Refit the lamp cover and tighten its screw firmly.
- The projector has two lamps replaced the same way; use the same lamp type in both, and when Dual lamp mode is selected replace lamps 1 and 2 together.
- If a bulb has shattered, do not touch the glass pieces; contact your NEC dealer.
- Lamp hours are stored in the lamp housing, so fitting a new lamp clears them automatically.