Dukane Image Pro 8782 projector – image: Dukane

Dukane Image Pro 8782 projector lamp

The Dukane Image Pro 8782 takes lamp DT00841, a 220 W lamp rated for 2,000 hours. It is available both as a complete module (bulb fitted in its housing) and as a bare bulb for re-using your existing housing. The same lamp is also sold under 7 other part numbers, all listed below. It fits 7 Dukane models in total.

Display Type0.63" 3LCD
Resolution1024x768
Brightness2,600 Lumens / 2,100 Lumens (Eco)
Light Source220W UHB bulb
DT00841 lamp with housing for the Dukane Image Pro 8782
✓The lamp that fits DT00841 projector lamp with module Primary code DT00841
Lamp with housingFits 34 models
Price on request Delivered price confirmed within one business hour. Full lamp details

Replacing the Dukane Image Pro 8782 lamp.

The Dukane Image Pro 8782 uses the DT00841 lamp. It is a 220W lamp rated for 2,000 hours in normal mode and 3,000 hours in Eco mode. We sell it as a complete module with the bulb fitted in its housing, and as a bare bulb for your existing housing. Every lamp we sell carries a genuine OEM burner.

The Image Pro 8782 is a 4:3 XGA projector with a 0.63-inch 3LCD display, 2,600 ANSI lumens in normal mode and a 500:1 contrast ratio. It was released in February 2008 and discontinued in June 2010. The lamp is shared with 6 other models, including the Image Pro 8781, Image Pro 8912 and Image Pro 8913.

To confirm the code, check the old lamp or the model label on the projector for DT00841 or one of its alternative codes. Pick the module for the quicker swap, or the bare bulb to reuse your existing housing. After fitting, reset the lamp-hour counter from the projector's menu and follow the user manual.

Checked against our catalogue and the projector's published specifications, October 2026.

Every code this lamp is sold under.

The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the Dukane Image Pro 8782.

CodeUsed by
DT00841Dukane original part number
456-8755GEquivalent code
78-6966-9917-2Equivalent code
RBB-009HEquivalent code
RLC-031Equivalent code
456-8775Equivalent code
456-8775HEquivalent code
X200LAMPEquivalent code

Check the code before you order

The code on your old lamp or its housing should match one of the codes listed. Dukane and third-party suppliers sell the same lamp under several numbers.

Not sure it's your model?

The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.

Dukane Image Pro 8782 specifications.

The figures that matter when you replace the lamp, plus the projector's key specs.

StatusDiscontinued Jun 2010
ReleasedFebruary 2008
Display Type0.63" 3LCD
Resolution1024x768
Aspect Ratio4:3 (XGA)
White Brightness2,600 Lumens (ANSI) / 2,100 Lumens (Eco)
Contrast500:1 (full on/off)
Light Source220W UHB bulb
Light Source Life2,000 hours / 3,000 hours (Eco)
Throw Ratio1.50:1 - 1.80:1
Throw Distance3.6' - 29.9'
Image Size30.00" - 300.00"
Lens ShiftNo
Digital KeystoneVertical only
Projector Size4.60" x 13.40" x 10.60" (HxWxD)
Weight8.8 lbs
Audible Noise33 dB / 29 dB (Eco)
Power320 Watts 100V - 240V
Internal Speakers7.0 Watts Mono
Connection PanelComponent: RCA Composite: RCA Network: RJ-45 RS232: DB-9pin S-Video USB: A VGA In: Dsub-15pin
Warranty5 Years
Replacement lampDT00841
Specifications: ProjectorCentral

This lamp also fits 6 other Dukane models.

If your projector is one of these rather than the Image Pro 8782, the same lamp is the correct part.

Common questions.

Which lamp does the Dukane Image Pro 8782 use?

The Dukane Image Pro 8782 uses the DT00841 lamp, which we sell as a complete module or as a bare bulb. Both versions are 220W lamps rated for 2,000 hours. The projector was released in February 2008 and discontinued in June 2010.

What other part numbers fit the Dukane Image Pro 8782?

The DT00841 module for the Dukane Image Pro 8782 is also sold as CPX400, RLC-031, RBB-009H, X200LAMP, 456-8755G, 78-6966-9917-2, 456-8775 and 456-8775H. The bare bulb is also sold as RLC-031, RBB-009H, 456-8755G and 78-6966-9917-2. Match your old lamp's code against these lists before ordering.

How long does the Image Pro 8782 lamp last?

The Dukane Image Pro 8782 lamp, DT00841, is rated for 2,000 hours in normal mode and 3,000 hours in Eco mode. Check the lamp-hour reading on the projector against those figures as the lamp ages.

Which other Dukane projectors use the same lamp?

6 other models share the DT00841 lamp with the Dukane Image Pro 8782, including the Image Pro 8755G and Image Pro 8755H. Owners of any of these can order the same lamp for their projector.

How do I know the Image Pro 8782 lamp needs replacing?

You can tell the Image Pro 8782 lamp needs replacing when the picture gets darker, the colors look off, or the lamp warning indicator comes on. The lamp-hour reading is also worth checking against the rated 2,000 hours in normal mode.

All Dukane projector lamps → All Dukane projector models A–Z →