Benq MW855UST projector – image: Benq

BenQ MW855UST projector lamp

The BenQ MW855UST takes lamp 5J.JC505.001, a 240 W lamp rated for 3,000 hours (6,000 hours in eco mode) . It is available both as a complete module (bulb fitted in its housing) and as a bare bulb for re-using your existing housing. It fits 4 BenQ models in total.

Display TypeDLP x 1
Resolution1280x800
Brightness3,500 Lumens
Light Source240W Metal Halide bulb
5J.JC505.001 lamp with housing for the BenQ MW855UST
✓The lamp that fits 5J.JC505.001 projector lamp with module Primary code 5J.JC505.001
Lamp with housingFits 4 models
Price on request Delivered price confirmed within one business hour. Full lamp details

Replacing the BenQ MW855UST lamp.

The BenQ MW855UST uses the 5J.JC505.001 lamp. It is a 240W metal halide bulb rated for 3,000 hours in normal mode and 6,000 hours in eco mode. We sell it as a complete module or a bare bulb.

The BenQ MW855UST is a WXGA DLP projector released in September 2015 and discontinued in May 2019. It has a single DLP chip, 1280x800 resolution and 3,500 ANSI lumens of brightness. Its contrast is 10,000:1, its throw ratio is 0.35:1 and it weighs 11.0 lbs. The same lamp also fits 3 other models, including the MH856UST+, MW855UST+ and MX854UST.

Before ordering, read the code printed on your old lamp or the model label. Both forms share the 5J.JC505.001 code. The complete module gives a quicker swap, because the bulb arrives already fitted in its housing. The bare bulb re-uses your existing housing, is the cheaper option, and is moved across by hand. After fitting, the lamp-hour counter should be reset from the projector's menu, as the user manual describes.

Checked against our catalogue and the projector's published specifications, October 2026.

Every code this lamp is sold under.

The code moulded into your old lamp or printed on its housing may be any of these. If it appears here, it fits the BenQ MW855UST.

CodeUsed by
5J.JC505.001BenQ original part number

Check the code before you order

The code on your old lamp or its housing should match one of the codes listed. BenQ and third-party suppliers sell the same lamp under several numbers.

Not sure it's your model?

The model number is on a label on the base or rear of the projector, and in the on-screen menu under Information. Still unsure? Ask a specialist and we'll confirm.

BenQ MW855UST specifications.

The figures that matter when you replace the lamp, plus the projector's key specs.

StatusDiscontinued May 2019
ReleasedSeptember 2015
Display TypeDLP x 1
Resolution1280x800
Aspect Ratio16:10 (WXGA)
Brightness3,500 Lumens (ANSI)
Contrast10,000:1 (full on/off)
Light Source240W Metal Halide bulb
Light Source Life3,000 hours / 6,000 hours (Eco)
Throw Ratio0.35:1
Throw Distance2.0' - 2.5'
Image Size79.65" - 100.27"
Lens ShiftVertical +8%
Digital KeystoneHorizontal & Vertical
Projector Size7.90" x 14.60" x 11.30" (HxWxD)
Weight11.0 lbs
Audible Noise34 dB / 29 dB (Eco)
Power320 Watts 100V - 240V
Internal Speakers10.0 Watts × 2
Connection PanelAudio In: Mini Jack Audio In: RCA Audio Out: Mini Jack Composite: RCA HDMI HDMI (MHL) Network: RJ-45 RS232: DB-9pin S-Video USB: A x 3 VGA In: Dsub-15pin x 2
3D ModesFull HD 3D
Warranty3 Years
Replacement lamp5J.JC505.001
Specifications: ProjectorCentral

This lamp also fits 3 other BenQ models.

If your projector is one of these rather than the MW855UST, the same lamp is the correct part.

Common questions.

Which lamp does the BenQ MW855UST use?

The BenQ MW855UST uses the 5J.JC505.001 lamp, a 240W metal halide bulb rated for 3,000 hours in normal mode and 6,000 hours in eco mode. It is available as a complete module or a bare bulb under the same code.

How long does the BenQ MW855UST lamp last?

The BenQ MW855UST lamp is rated for 3,000 hours in normal mode and 6,000 hours in eco mode. The projector specification gives the same figures for its light source life. Compare the lamp-hours reading on the projector with those figures to plan a replacement.

Should I buy the module or the bare bulb for the BenQ MW855UST?

Both forms are sold for the BenQ MW855UST under the 5J.JC505.001 code. The complete module suits a quicker swap, as the bulb arrives already fitted in its housing. The bare bulb suits anyone keeping their existing housing, and it is the cheaper option, with the bulb moved across by hand.

How do I know the BenQ MW855UST lamp needs replacing?

The BenQ MW855UST lamp is due for replacement when you see dimming, a color shift or a lamp warning, or when its lamp-hours reading nears 3,000 hours. Compare that reading with the 3,000 hour rating in normal mode, and check the user manual if a warning appears.

Which other BenQ projectors use the same lamp?

The BenQ MW855UST shares its 5J.JC505.001 lamp with 3 other models, including the MH856UST+, MW855UST+ and MX854UST. All three use the same lamp, so owners can check the 5J.JC505.001 code against their own projector before ordering.

All BenQ projector lamps → All BenQ projector models A–Z →

The BenQ MW855UST lamp at a glance.

Lamp5J.JC505.001
Lamp power240 W
Figures from BenQ's documentation for the MW855UST: source.

Replacing the lamp in the BenQ MW855UST.

  1. Switch the projector off, unplug it and let it cool for at least 45 minutes; if it is ceiling-mounted, keep everyone clear of the area below the lamp socket.
  2. Loosen the screw on the right side and take off the lamp compartment cover.
  3. Loosen the two captive screws holding the lamp, raise the handle upright and pull the lamp out slowly (pulling fast can break it).
  4. Insert the new lamp with its connectors aligned; if it meets resistance, lift it and try again.
  5. Tighten the lamp screws without over-tightening and lay the handle flat until it locks.
  6. Refit the lamp cover and tighten its screw; never switch on with the cover removed.
  7. Restart the projector and reset the lamp timer.
Steps summarised from BenQ's manual for the MW855UST: source.

Then reset the lamp timer.

Until you reset it, the MW855UST keeps counting from the old lamp's hours and will warn that the new lamp is expiring.

SYSTEM SETUP: Advanced → Lamp Settings → Reset lamp timer → Reset